Owners Manual

Dell Integrated Systems for Oracle Business Analytics (DISOBA) Owner’s Guide 1.0
3.2 S6000 Switch Configurations
This section provides the details of the configuration that the S6000 switches ship with.
3.2.1 S6000 Pre-defined Port Functions
Using one of the S6000 switches as an example, the following figure shows the details of
the pre-defined port functions and configuration.
S6000 Port Functions and Configurations
The pre-defined port functions are as follows:
Ports 0/0, 0/8, 0/18 and 0/24 are configured as FortyGigE ports and are used for
Oracle database’s private interconnect network. These ports are pre-cabled and
connected to the private network ports of the database nodes. 0/18 and 0/24 are
not pre-cabled but are reserved for future database node expansion.
Ports 0/4, 0/12, 0/20 and 0/28 are configured as FortyGigE ports and are used for
Oracle database’s public network. These ports are pre-cabled and connected to
the database nodes’ public network ports. 0/20 and 0/28 are not pre-cabled but
are reserved for future database node expansion.
Port range 0/32-44 are configured as FortyGigE ports and are reserved for
connectivity to other Dell Integrated Systems.
Port ranges 0/48-60 and ports 0/96, 0/104, 0/112 and 0/120 are configured as
FortyGigE ports with un-defined functionality or usage.
Port ranges 0/64-79 are configured as TenGigE ports and are used for connecting
to customer’s 10GbE network environment. The FortyGigE port 0/68 ships with a
QSFP+ to 4 x SFP+ 10GbE direct attach breakout cable. The TenGigE port 0/68,
0/69 in that is pre-cabled and connected to the 10GbE module on the S60 switch,
Mellanox card on the R730.
Port ranges 0/80-92 are configured as FortyGigE ports and are used for
connecting to customer’s 40GbE network environment.
Ports 0/100, 0/108, 0/116 and 0/124 are configured as FortyGigE ports and are
used as VLTi trunk ports. They are connected to the corresponding VLTi trunk
ports on the other S6000 switch.