Release Notes

Tracking number 139240
Persistent Memory displayed after removing
Apache Pass DIMM (AEP)
Description Resetting iDRAC and restarting the system simultaneously may cause iDRAC GUI to display the persistent
memory option even after the AEP DIMM’s were removed from the system.
Workaround Reset iDRAC again after the system POST is complete.
Systems affected All systems supported by this release.
Tracking number 118156
iDRAC IP changes to 0.0.0.0 temporarily during
power cycles
Description During a Host reboot if the network interface goes down for brief period, iDRAC loses its IP address until the
network interface is back up. The LC logs display messages about "iDRAC IP Address changed from X.X.X.X to
0.0.0.0" then "0.0.0.0" to "X.X.X.X".
Workaround N/A
Systems affected All systems supported by this release.
Tracking number 120132
After a warm reboot, LC logs display Disk Inserted
Description
After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please
ignore the log entry.
Workaround N/A
Systems affected All systems supported by this release.
Tracking number 144819 and 141414
SMART not reporting for some drives
Description
SMART monitoring is disabled for a hard drive while it is set to Non-Raid mode.
Workaround N/A
Systems affected All systems supported by this release.
Tracking number 135660
18 Known issues — To be fixed in future releases