Users Guide

Table Of Contents
XenServer 7.1
For Linux operating systems, configure the USB NIC as DHCP on the host operating system before enabling USB NIC.
For vSphere, you must install the VIB file before enabling USB NIC.
NOTE: To configure USB NIC as DHCP in Linux operating system or XenServer, refer to the operating system or hypervisor
documentation.
Installing VIB file
For vSphere operating systems, before enabling the USB NIC, you must install the VIB file.
To install the VIB file:
1. Using Win-SCP, copy the VIB file to /tmp/ folder of the ESX-i host operating system.
2. Go to the ESXi prompt and run the following command:
esxcli software vib install -v /tmp/ iDRAC_USB_NIC-1.0.0-799733X03.vib --no-sig-check
The output is:
Message: The update completed successfully, but the system needs to be rebooted for
the changes to be effective.
Reboot Required: true
VIBs Installed: Dell_bootbank_iDRAC_USB_NIC_1.0.0-799733X03
VIBs Removed:
VIBs Skipped:
3. Reboot the server.
4. At the ESXi prompt, run the command: esxcfg-vmknic l.
The output displays the usb0 entry.
Enabling or disabling OS to iDRAC Pass-through using web
interface
To enable OS to iDRAC Pass-through using Web interface:
1. Go to iDRAC Settings > Connectivity > Network > OS to iDRAC Pass-through.
The OS to iDRAC Pass-through page is displayed.
2. Change the State to Enabled.
3. Select any of the following options for Pass-through Mode:
LOM The OS to iDRAC pass-through link between the iDRAC and the host operating system is established through
the LOM or NDC.
USB NIC The OS to iDRAC pass-through link between the iDRAC and the host operating system is established
through the internal USB bus.
4. If you select LOM as the pass-through configuration, and if the server is connected using dedicated mode, enter the IPv4
address of the operating system.
NOTE: If the server is connected in shared LOM mode, then the OS IP Address field is disabled.
NOTE: If the VLAN is enabled on the iDRAC, the LOM-Passthrough will only function in shared LOM mode with VLAN
tagging configured on the host.
5. If you select USB NIC as the pass-through configuration, enter the IP address of the USB NIC.
The default value is 169.254.1.1. It is recommended to use the default IP address. However, if this IP address conflicts with
an IP address of other interfaces of the host system or the local network, you must change it.
Do not enter 169.254.0.3 and 169.254.0.4 IPs. These IPs are reserved for the USB NIC port on the front panel when a A/A
cable is used.
6. Click Apply.
Configuring iDRAC
93