Users Guide

Table Of Contents
To schedule the start time and frequency of the firmware update:
racadm AutoUpdateScheduler create -u username p password l <location> [-f
catalogfilename -pu <proxyuser> -pp<proxypassword> -po <proxy port> -pt <proxytype>]
-time < hh:mm> [-dom < 1 28,L,*’> -wom <1-4,L,*> -dow <sun-sat,*>] -rp <1-366>
-a <applyserverReboot (1-enabled | 0-disabled)>
For example,
To automatically update firmware using a CIFS share:
racadm AutoUpdateScheduler create -u admin -p pwd -l //1.2.3.4/CIFS-share f
cat.xml -time 14:30 -wom 1 -dow sun -rp 5 -a 1
To automatically update firmware using FTP:
racadm AutoUpdateScheduler create -u admin -p pwd -l ftp.mytest.com -pu puser pp
puserpo 8080 pt http f cat.xml -time 14:30 -wom 1 -dow sun -rp 5 -a 1
To view the current firmware update schedule:
racadm AutoUpdateScheduler view
To disable automatic firmware update:
racadm set lifecycleController.lcattributes.AutoUpdate.Enable 0
To clear the schedule details:
racadm AutoUpdateScheduler clear
Upload the update file from a remote HTTP share:
racadm update -f <updatefile> -u admin -p mypass -l http://1.2.3.4/share
Upload the update file from a remote HTTPS share:
racadm update -f <updatefile> -u admin -p mypass -l https://1.2.3.4/share
Updating firmware using CMC web interface
You can update iDRAC firmware for blade servers using the CMC Web interface.
To update iDRAC firmware using the CMC Web interface:
1. Log in to CMC Web interface.
2. Go to iDRAC Settings > Settings > CMC.
The Deploy iDRAC page is displayed.
3. Click Launch iDRAC Web interface and perform iDRAC Firmware Update.
Updating firmware using DUP
Before you update firmware using Dell Update Package (DUP), make sure to:
Install and enable the IPMI and managed system drivers.
Enable and start the Windows Management Instrumentation (WMI) service if your system is running Windows operating
system,
NOTE:
While updating the iDRAC firmware using the DUP utility in Linux, if you see error messages such as usb 5-2:
device descriptor read/64, error -71 displayed on the console, ignore them.
If the system has ESX hypervisor installed, then for the DUP file to run, make sure that the "usbarbitrator" service is stopped
using command: service usbarbitrator stop
To update iDRAC using DUP:
1. Download the DUP based on the installed operating system and run it on the managed system.
70