Users Guide

Table Of Contents
You must have Server Control privilege to modify this setting.
NOTE: You cannot set the SGPIO mode using iDRAC Web interface.
Setting SGPIO mode using RACADM
To configure the SGPIO mode, use the set command with the objects in the SGPIOMode group.
If it is set to disabled, it is I2C mode. If enabled, it is set to SGPIO mode.
For more information, see the iDRAC RACADM Command Line Interface Reference Guide available at dell.com/idracmanuals.
Set Enclosure Asset Tag
Set Enclosure Asset Tag allows you to configure Asset Tag of a storage enclosure.
User can change the Asset Tag property of the enclosure to identify enclosures. These fields are checked for invalid values and
an error is displayed if an invalid value is entered. These fields are part of the enclosure firmware; the data initially shown are the
values saved in the firmware.
NOTE: Asset Tag has a character limit of 10 that includes the null character.
NOTE: These operations are not supported on internal enclosures.
Set Enclosure Asset Name
Set Enclosure Asset Name allows the user to configure the Asset Name of a storage enclosure.
The user can change the Asset Name property of the enclosure to identify enclosures easily. These fields are checked for invalid
values and an error is displayed if an invalid value is entered. These fields are part of the enclosure firmware; the data initially
shown are the values saved in the firmware.
NOTE: Asset Name has a character limit of 32 that includes the null character.
NOTE: These operations are not supported on internal enclosures.
Choosing operation mode to apply settings
While creating and managing virtual disks, setting up physical disks, controllers, and enclosures or resetting controllers, before
you apply the various settings, you must select the operation mode. That is, specify when you want to apply the settings:
Immediately
During the next system reboot
At a scheduled time
As a pending operation to be applied as a batch as part of a single job.
Choosing operation mode using web interface
To select the operation mode to apply the settings:
1. You can select the operation mode on when you are on any of the following pages:
Storage > Physical Disks .
Storage > Virtual Disks
Storage > Controllers
Storage > Enclosures
2. Select one of the following from the Apply Operation Mode drop-down menu:
Apply Now Select this option to apply the settings immediately. This option is available for PERC 9 controllers only. If
there are jobs to be completed, then this option is grayed-out. This job take at least 2 minutes to complete.
Managing storage devices
229