Users Guide

Table Of Contents
Feature Name PERC 10 Controllers PERC 9 Controllers PCIe
SSD
H740P
Mini
H740P
Adapter
H840
Adapter
H330
Mini
H330
Adapte
r
H730P
Mini
H730P
Adapte
r
FD33x
S
Blink or unblink
component LEDs
Real-time Real-time Real-time Real-
time
Real-
time
Real-time Real-
time
Real-
time
Real-time
Switch controller mode Not
applicable
Not
applicable
Not
applicable
Staged Staged Staged Staged Staged Not
applicable
T10PI support for
Virtual Disks
Not
applicable
Not
applicable
Not
applicable
Not
applicabl
e
Not
applicabl
e
Not
applicabl
e
Not
applicab
le
Not
applicab
le
Not
applicable
NOTE: PERC 10 no longer supports convert drives to non-RAID, convert controller to HBA mode and RAID 10 uneven span
support.
Inventorying and monitoring storage devices
You can remotely monitor the health and view the inventory of the following Comprehensive Embedded Management (CEM)
enabled storage devices in the managed system using iDRAC web interface:
RAID controllers, non-RAID controllers, BOSS controllers and PCIe extenders
Enclosures that include Enclosure Management Modules (EMMs), power supply, fan probe, and temperature probe
Physical disks
Virtual disks
Batteries
The recent storage events and topology of storage devices are also displayed.
Alerts and SNMP traps are generated for storage events. The events are logged in the Lifecycle Log.
NOTE:
For an accurate inventory of BOSS controllers, ensure that Collect System Inventory On Reboot Operation (CSIOR)
is completed. CSIOR is enabled by default.
NOTE: If you enumerate the enclosure view's WSMan command on a system while one PSU-cable is removed, the primary
status of the enclosure view is reported as Healthy instead of Warning.
NOTE: The storage health rollup follows the same convention of Dell EMC OpenManage product. For more information see
the OpenManage Server Administrator User's Guide available at https://www.dell.com/openmanagemanuals.
NOTE: Physical disks in system with multiple backplanes may be listed under a different backplane. Use the blink function
to identify the disks.
Monitoring storage devices using web interface
To view the storage device information using web interface:
Go to Storage > Overview > Summary to view the summary of the storage components and the recently logged events.
This page is automatically refreshed every 30 seconds.
Go to Storage > Overview > Controllers to view the RAID controller information. The Controllers page is displayed.
Go to Storage > Overview > Physical Disks to view physical disk information. The Physical Disks page is displayed.
Go to Storage > Overview > Virtual Disks to view virtual disk information. The Virtual Disks page is displayed.
Go to Storage > Overview > Enclosures to view the enclosure information. The Enclosures page is displayed.
You can also use filters to view specific device information.
NOTE: The storage hardware list is not displayed in case the system does not have storage devices with CEM support.
NOTE: When NVMe SSDs are in RAID mode behind S140 controller, web interface does not display NVMe SSDs slot
information in the Enclosure page. Refer Physical Disks page for the details.
202 Managing storage devices