Monitoring FC HBA devices using RACADM
To view the FC HBA device information using RACADM, use the hwinventory command.
For more information, see the iDRAC RACADM CLI Guide available at https://www.dell.com/idracmanuals.
Dynamic configuration of virtual addresses, initiator,
and storage target settings
You can dynamically view and configure the virtual address, initiator and storage target settings, and apply a persistence policy.
It allows the application to apply the settings based on power state changes (that is, operating system restart, warm reset,
cold reset, or AC cycle) and also based on persistence policy setting for that power state. This provides more flexibility in
deployments that need rapid re-configuration of system workloads to another system.
The virtual addresses are:
Virtual MAC Address
Virtual iSCSI MAC Address
Virtual FIP MAC Address
Virtual WWN
Virtual WWPN
NOTE: When you clear the persistence policy, all the virtual addresses are reset to the default permanent address set at
the factory.
NOTE: Some cards with the virtual FIP, virtual WWN, and virtual WWPN MAC attributes, the virtual WWN and virtual
WWPN MAC attributes are automatically configured when you configure virtual FIP.
Using the IO Identity feature, you can:
View and configure the virtual addresses for network and fibre channel devices (for example, NIC, CNA, FC HBA).
Configure the initiator (for iSCSI and FCoE) and storage target settings (for iSCSI, FCoE, and FC).
Specify persistence or clearance of the configured values over a system AC power loss, cold, and warm system resets.
The values configured for virtual addresses, initiator and storage targets may change based on the way the main power is
handled during system reset and whether the NIC, CNA, or FC HBA device has auxiliary power. The persistence of IO identity
settings can be achieved based on the policy setting made using iDRAC.
Only if the I/O identity feature is enabled, the persistence policies take effect. Each time the system resets or powers on, the
values are persisted or cleared based on the policy settings.
NOTE: After the values are cleared, you cannot re-apply the values before running the configuration job.
Supported cards for IO Identity Optimization
The following table provides the cards that support the I/O Identity Optimization feature.
Table 39. Supported cards for I/O Identity Optimization (continued)
Manufacturer Type
Broadcom
5719 Mezz 1GB
5720 PCIe 1 GB
5720 bNDC 1 GB
5720 rNDC 1 GB
57414 PCIe 25GbE
Intel
i350 DP FH PCIe 1GB
i350 QP PCIe 1GB
i350 QP rNDC 1GB
i350 Mezz 1GB
i350 bNDC 1GB