NOTE: To activate IPMI SOL, you must have the minimum privilege defined in IMPI SOL. For more information, see the
IPMI 2.0 specification.
3. Update the IPMI SOL baud rate using the command.
racadm set iDRAC.IPMISol.BaudRate <baud_rate>
NOTE: To redirect the serial console over LAN, make sure that the SOL baud rate is identical to the managed systems
baud rate.
Parameter Allowed values (in bps)
<baud_rate>
9600, 19200, 57600, and 115200.
4. Enable SOL for each user using the command.
racadm set iDRAC.Users.<id>.SolEnable 2
Parameter Description
<id>
Unique ID of the user
NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate is identical to the baud rate of the managed
system.
Enabling supported protocol
The supported protocols are IPMI, SSH, and Telnet.
Enabling supported protocol using web interface
To enable SSH or Telnet, go to iDRAC Settings > Services and select Enabled for SSH or Telnet, respectively.
To enable IPMI, go to iDRAC Settings > Connectivity and select IPMI Settings. Make sure that the Encryption Key value is
all zeroes or press the backspace key to clear and change the value to NULL characters.
Enabling supported protocol using RACADM
To enable the SSH or Telnet, use the following commands.
Telnet
racadm set iDRAC.Telnet.Enable 1
SSH
racadm set iDRAC.SSH.Enable 1
To change the SSH port
racadm set iDRAC.SSH.Port <port number>
You can use tools such as:
IPMItool for using IPMI protocol
Putty/OpenSSH for using SSH or Telnet protocol