Release Notes

To change the Primary PSU value, ensure that HotSpare is enabled.
Version/Systems affected: All systems supported by this release.
Dell tracking: 63313
13. Description
When NVMe drives are set to RAID mode, storage configuration page error message is incomplete.
Resolution
The current message is generic for all SSDs. NVMe-specific message text will be updated in a future release. For more details, see the
iDRAC integrated help.
Version/Systems affected: All systems supported by this release.
Dell tracking: 63058
14. Description
An ambiguous message Unable to log in for 1@@1404816348 from ... is logged in Lifecycle logs (LCL).
Resolution
If the iDRAC is rebooted while a vConsole session is active, the vConsole attempts to reconnect with the server. If the vConsole has
not been closed or timed out after the iDRAC reboots, the vConsole attempts to reconnect and is denied access because its
temporary credentials are no longer valid. This causes the LCL to log the message
Unable to log in for X@@XXXXXXXX
from <IP ADDRESS> using Virtual Console.
Version/Systems affected: All systems supported by this release.
Dell tracking: 61221
15. Description
Using iDRAC GUI interface, you may be unable to export the Lifecycle logs to a CIFS network share. The following error message is
displayed: RAC0509: The server is temporarily unavailable. Wait for a few minutes and refresh the
page. If the problem persists, contact service provider.
Resolution
From iDRAC GUI, export Lifecycle logs using local or NFS network share options. You can also use RACADM to export the Lifecycle
logs.
Version/Systems affected: All systems supported by this release.
Dell tracking: 60183
16. Description
In iDRAC GUI, closing the HTML5 virtual console session by exiting the browser does not terminate the mounted VMedia session.
Because of this, you cannot connect to virtual media on your next virtual console session.
Resolution
To terminate the VMedia session, click Disconnect Viewer.
Version/Systems affected: All systems supported by this release.
Dell tracking: 63411
17. Description
If no hard drive is inserted on systems with direct attached SSD, PCIe Capable is displayed as No.
Resolution
For backplane with direct attached PCIe SSD devices, PCIe capability is shown as No for empty slots. Both SSDs and HDDs can be
inserted in universal slots. See your server configuration to get the details for PCIe capability.
Version/Systems affected: All systems supported by this release.
Dell tracking: 63456
18. Description
In iDRAC GUI, inlet warning threshold for iDRAC temperature probes cannot be set to 0.
Resolution
Set the warning threshold [minimum/maximum] value to 0 (Zero) using RACADM.
Version/Systems affected: All systems supported by this release.
Dell tracking: 63315
Known Issues — To be fixed in future releases