Users Guide

Setting up managed system location using web interface
To specify the system location details:
1. In the iDRAC web interface, go to System > Details > System Details.
The System Details page is displayed.
2. Under System Location, enter the location details of the managed system in the data center.
For information about the options, see the iDRAC Online Help.
3. Click Apply. The system location details are saved in iDRAC.
Setting up managed system location using RACADM
To specify the system location details, use the System.Location group objects.
For more information, see the iDRAC RACADM Command Line Interface Reference Guide available at dell.com/idracmanuals.
Setting up managed system location using iDRAC settings
utility
To specify the system location details:
1. In the iDRAC Settings utility, go to System Location.
The iDRAC Settings System Location page is displayed.
2. Enter the location details of the managed system in the data center. For information about the options, see the iDRAC Settings Utility
Online Help.
3. Click Back, click Finish, and then click Yes.
The details are saved.
Optimizing system performance and power
consumption
The power required to cool a server can contribute a significant amount to the overall system power. Thermal control is the active
management of system cooling through fan speed and system power management to make sure that the system is reliable while
minimizing system power consumption, airflow, and system acoustic output. You can adjust the thermal control settings and optimize
against the system performance and performance-per-Watt requirements.
Using the iDRAC Web interface, RACADM, or the iDRAC Settings Utility, you can change the following thermal settings:
Optimize for performance
Optimize for minimum power
Set the maximum air exhaust temperature
Increase airflow through a fan offset, if required
Increase airflow through increasing minimum fan speed
Modifying thermal settings using iDRAC web interface
To modify the thermal settings:
1. In the iDRAC Web interface, go to Configuration > System Settings > Hardware Settings > Fans configuration.
The Fan Setup page is displayed.
2. Specify the following:
Thermal Profile — Select the thermal profile:
Default Thermal Profile Settings — Implies that the thermal algorithm uses the same system profile settings that is defined
under System BIOS > System BIOS Settings.System Profile Settings page.
By default, this is set to Default Thermal Profile Settings. You can also select a custom algorithm, which is independent of the
BIOS profile. The options available are:
52
Setting up managed system