Release Notes
If iDRAC to OS pass-through is disabled, SupportAssist registration may display error messages.
Resolution
Enable OS to iDRAC pass-through in iDRAC GUI. To enable the setting, go to iDRAC Settings > Connectivity > OS to iDRAC
Pass-through.
Version/Systems affected: All systems supported by this release.
Dell tracking: 64465
27. Description
While creating a virtual disk using NVMe physical disks, the LC RAID Configuration Wizard displays blank values for Read Policy, Write
Policy, and Disk Cache Policy selections, but default settings are shown for the virtual disk in the Summary page.
Resolution
N/A. There are no user-selectable options for these settings.
Version/Systems affected: All systems supported by this release.
Dell tracking: 59051
28. Description
While setting AssetName and AssetTag for an external enclosure, the Lifecycle Logs as well as the job's ConfigResults do not contain
the attribute or the value that was set.
Resolution
N/A
Version/Systems affected: All systems supported by this release.
Dell tracking: 61929
29. Description
If the host is powered off, the command to set AssetName and AssetTag for an external enclosure fails.
Resolution
To set AssetName or AssetTag, ensure that the host is powered on.
Version/Systems affected: All systems supported by this release.
Dell tracking: 61932
30. Description
After a SecureErase or PrepareToRemove job for a PCIe SSD in a universal slot, the iDRAC GUI Storage Overview page does not
display any PCIe SSD in the Enclosure view for the universal backplane.
Resolution
Restart the iDRAC to display the PCIe SSDs in the Enclosure view.
Version/Systems affected: All systems supported by this release.
Dell tracking: 64010
31. Description
Using Lifecycle Controller, if you try to update firmware (except driver pack, ISM, OS collector, diagnostic DUPs) and the firmware
partition is full, the following warning message is displayed: Insufficient space to store the firmware images.
Deleting all rollback firmware images. Do you want to continue? If you click No, the previous screen is
displayed and if you click
Apply again to update the firmware, the same warning message is displayed. If you click Yes, the update
operation fails.
Resolution
To complete the firmware update operation:
• Click Yes when the warning message is displayed for the first time.
• If you clicked 'No' when the warning was displayed for the first time, go to the previous page (Step 2 of 3: Enter Access Details)
and start the update again. When the warning message is displayed, click Yes to complete the update.
If you do not want to delete the rollback firmware image, you can cancel the update.
a. Click No on the warning message.
b. On the Lifecycle Controller page (Step 3 of 3: Select Updates), click Cancel.
Version/Systems affected: All systems supported by this release.
Known Issues — To be fixed in future releases