Release Notes
While creating a vFlash partition from an image using iDRAC GUI, you may be able to attach files with invalid extension if the file type is
selected as 'All Files' in the file browser. However, the emulation on the OS fails.
Resolution
When creating a vFlash partition from image in iDRAC GUI, default file type is set in the file browser based on the emulation type. Do
not change the file type to 'All Files'. If changing the file type for any reason, always choose files with .iso extension for CD emulation
type and files with .img extension for floppy drive/HDD.
Version/Systems affected: All systems supported by this release.
Dell tracking: 61962
7. Description
When you launch the virtual console sessions from the iDRAC GUI using HTML5 plugin the session sharing window does not display
the requester name. The following text is missing: A connection request has been received from user:
<username>.
Resolution
You can still accept or reject the session sharing request.
Version/Systems affected: All systems supported by this release.
Dell tracking: 62812
8. Description
Creating RAID-5 Virtual Disk using NVMe drives with the PERC S140 controller fails due to PERC S140 firmware limitations.
Resolution
N/A
Version/Systems affected: All systems supported by this release.
Dell tracking: N/A
9. Description
Windows operating system (OS) installation initiated from LC with the PERC S140 storage controller cannot be completed without
loading driver for PERC S140. This step is required because S140 drivers are not part of the OS driver pack.
Resolution
To install the driver, click Load driver on the windows installation page, select PERC S140 drivers path, and click Next. After the
driver installation is complete, select the virtual disk and click
Next to complete the OS installation.
Version/Systems affected: All systems supported by this release.
Dell tracking: N/A
10. Description
When using SCP Export JSON with the 'Include Read Only' option, the resulting JSON file does not contain read-only attributes for
RAID components.
Resolution
Use SCP Export with the default XML format instead of JSON to access these read-only RAID attributes.
Version/Systems affected: All systems supported by this release.
Dell tracking: 62939
11. Description
When performing catalog updates simultaneously with OS driver pack and iDRAC DUPs, depending on the number of updates being
performed, one of these updates may not get downloaded from repository due to size limit.
Resolution
Retry the catalog update operation after previous operation completes.
Version/Systems affected: All systems supported by this release.
Dell tracking: N/A
12. Description
In iDRAC GUI, modifying the HotSpare value to disabled and reloading Power Management screen does not disable the Primary PSU
options. You may be able to change the Primary PSU but the modified value do not get applied because HotSpare is disabled.
Resolution
16
Known Issues — To be fixed in future releases