CLI Guide

Table Of Contents
Table 455. Details of System.Power.PCIeAllocation (continued)
Legal Values
0 Disabled
1 Enabled
Default Value
0 For platforms that do not support PCIe cards.
500 W For platforms that support PCIe cards.
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.PFCEnable (Read or Write)
Table 456. Details of System.Power.PFCEnable
Description
Enables the power factor correction enable.
NOTE:
This object is supported only for iDRAC on Rack and Tower servers.
This object is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values
0 Disabled
1 Enabled
Default Value
0 Disabled
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.RedundancyCapabilities (Read Only)
Table 457. Details of System.Power.RedundancyCapabilities
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask indicates the values that are set
to cfgSensorRedundancyPolicy.
NOTE: This object is not applicable for iDRAC on Blade servers.
Legal Values
0 not applicable
1 Non-Redundant
2 1+1 Redundant
4 2+1 Redundant
8 2+2 Redundant
16 3+x Redundant
32 4+x Redundant
64 5+x Redundant
Default Value
0 not applicable
Write Privilege Not Applicable
262 Database Objects With Get and Set Commands