CLI Guide

Table Of Contents
NIC.IscsiSecondTgtParams
NIC.NICConfig
NIC.NICPartitioningConfig
NIC.VndrConfigGroup
NIC.VndrConfigPage
Storage.Controller
Storage.enclosure
Storage.PhysicalDisk
Storage.VirtualDisk
System.Backplane
The objects in this group manage the backplane.
System.Backplane.BackplaneBusMode (Read Only)
Table 383. Details of System.Backplane.BackplaneBusMode
Description Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode.
Legal Values
0 Unknown
1 I2C
2 SGPIO
Default Value 1 I2C
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ChassisControl
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To control the chassis related
events, use this group.
System.ChassisControl.ChassisManagementMonitoring (Read or
Write)
Table 384. Details of System.ChassisControl.ChassisManagementMonitoring
Description Enables or disables the event forwarding from CMC.
Legal Values
0 Disabled
1 Enabled
Default value 1 Enabled
Write Privilege Server Control
License
Required
Base
Dependency ChassisMangamentAt server object.
Database Objects With Get and Set Commands 239