Table 241. Example (continued)
Access Virtual Media 0x00000040
Test Alerts 0x00000080
Execute Debug Commands 0x00000100
cfgThermal
This group displays and configures the thermal settings. Use this object with the config or getconfig subcommands.
To set the configurations, you must have the Chassis Configuration Administrator privileges.
cfgThermalEnhancedCoolingMode (Read or Write)
Table 242. Details of cfgThermalEnhancedCoolingMode attribute
Description
Configures the enhanced cooling mode.
Legal Values
1 Enabled
0 Disabled
Default 0 Disabled
cfgIpmiSol
This group is used to configure the Serial Over LAN (SOL) capabilities of the system.
The following sections provide information about the objects in the cfgIpmiSol group.
cfgIpmiSolEnable (Read or Write)
Table 243. Details of cfgIpmiSolEnable
Description
Enables or disables SOL.
Legal Values
1(TRUE)
0(FALSE)
Default
1
cfgIpmiSolBaudRate (Read or Write)
Table 244. Details of cfgIpmiSolBaudRate
Description
Specifies baud rate for serial communication over LAN.
Legal Values
9600, 19200, 57600, 115200
Default
115200
iDRAC Property Database Group and Object Descriptions 199