CLI Guide

Table Of Contents
cfgSerialSshEnable - Read or Write
Table 167. Details of cfgSerialSshEnable attribute
Description
Enables or disables the secure shell (SSH) interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
Example
racadm getconfig -g cfgSerial
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=1800
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=
cfgSerialConsoleColumns=0
cfgSerialHistorySize=8192
cfgSerialTelnetEnable=0
cfgSerialSshEnable=1
cfgSerialTelnetEnable - Read or Write
Table 168. Details of cfgSerialTelnetEnable attribute
Description
Enables or disables the Telnet console interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgOobSnmp
This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC. One instance of the group is
allowed.
This group contains parameters to configure the SNMP agent and trap capabilities of CMC. One instance of the group is
allowed.
The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB.
This group is not applicable for iDRAC on Rack and Tower Servers.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE:
You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the o option.
The following sections provide information about the objects in the cfgOobSnmp group.
iDRAC Property Database Group and Object Descriptions
177