CLI Guide

Table Of Contents
Table 146. Details of cfgUserAdminEnable attribute (continued)
Legal Values
1 (TRUE)
0(FALSE)
Default
1 (User 2), 0 (All others)
0
cfgUserAdminSolEnable (Read or Write)
Table 147. Details of cfgUserAdminSolEnable
Description Enables or disables Serial Over LAN (SOL) user access for the user.
Legal Values
1 (TRUE)
0(FALSE)
Default
0
cfgEmailAlert
This group contains parameters to configure iDRAC email alerting capabilities. Up to four instances of this group are allowed.
This group contains parameters to configure CMC email alerting capabilities. Up to four instances of this group are allowed.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privileges.
NOTE:
You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the o option.
The following sections provide information about the objects in the cfgEmailAlert group.
cfgEmailAlertIndex - Read Only
Table 148. Details of cfgEmailAlertIndex attribute
Description
The unique index of an alert instance.
Legal Values
14
Default
<instance>
cfgEmailAlertEnable - Read or Write
Table 149. Details of cfgEmailAlertEnable attribute
Description
Enables or disables the alert instance.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
iDRAC Property Database Group and Object Descriptions 171