CLI Guide

Table Of Contents
Table 92. Details of storage (continued)
To view the help details for a configuration command, run
the following command:
racadm storage help <command>
where command can take below values
converttoraid, converttononraid,
controllers, clearconfig,
createsecuritykey, createvd,
deletesecuritykey, deletevd,
encryptvd, enclosures, emms,
fans, hotspare, importconfig,
ccheck, secureerase, preparetoremove,
blink, unblink, cancelcheck, init,
modifysecuritykey, psus, pdisks,
resetconfig, tempprobes, vdisks,
cancelbgi,
replacephysicaldisk, setbootvd,
forceonline, forceoffline, unlock and
patrolread.
To create, delete, and secure the virtual disks. To start or
stop the consistency check on the specified virtual disk,
run the following command:
racadm storage createvd:<Controller
FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-
wp {wt|wb|wbf}] [-rp {nra|ra|ara}] [-
ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|
512k|1M|2M|4M|8M|16M}]-pdkey:<comma
separated PD FQDD> [-dcp {enabled|
disabled|default}] [-name <VD name>]
[-size <VD size>{b|k|m|g|t}] [-
T10PIEnable]
NOTE:
T10PI is not supported on PERC 9 and PERC
10.
racadm storage init:<VD FQDD> -speed
{fast|full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage
createsecuritykey:<Controller FQDD>
-key <Key id> -xxx <passphrase>
NOTE:
createsecuritykey command is not supported
on H3xx PERC controllers.
racadm storage
modifysecuritykey:<Controller FQDD>
126
RACADM Subcommand Details