Table 8. Thermal Settings (continued)
Object Description Usage Example
results in fan speed increasing
to full speed.
racadm set
system.thermalsettin
gs FanSpeedOffset 3
FanSpeedMediumOffsetVa
l
• Getting this variable reads
the fan speed offset value in
%PWM for Medium Fan
Speed Offset setting.
• This value depends on the
system.
• Use FanSpeedOffset
object to set this value using
index value 2
Values from 0-100
racadm get
system.thermalsettin
gs
FanSpeedMediumOffset
Val
This returns a value such as
“47”. This means that when you
use the following command, it
applies a fan speed offset of
Medium (47% PWM) over
baseline fan speed
racadm set
system.thermalsettin
gs FanSpeedOffset 2
FanSpeedOffset
• Using this object with get
command displays the
existing Fan Speed Offset
value.
• Using this object with set
command allows setting the
required fan speed offset
value.
• The index value decides the
offset that is applied and the
FanSpeedLowOffsetVal
,
FanSpeedMaxOffsetVal
,
FanSpeedHighOffsetVa
l, and
FanSpeedMediumOffset
Val objects (defined earlier)
are the values at which the
offsets are applied.
Values are:
• 0 — Low Fan Speed
• 1 — High Fan Speed
• 2 — Medium Fan Speed
• 3 — Max Fan Speed
• 255 — None
To view the existing setting:
racadm get
system.thermalsettin
gs.FanSpeedOffset
To set the fan speed offset to
High value (as defined in
FanSpeedHighOffsetVal)
racadm set
system.thermalsettin
gs.FanSpeedOffset 1
MFSMaximumLimit
Read Maximum limit for MFS
Values from 1 — 100 To display the highest value that
can be set using
MinimumFanSpeed option:
racadm get
system.thermalsettin
gs.MFSMaximumLimit
54 Setting up managed system and management station