Table 8. Thermal Settings (continued)
Object Description Usage Example
results in fan speed increasing
to full speed.
racadm set
system.thermalsettin
gs FanSpeedOffset 3
FanSpeedMediumOffsetVa
l
Getting this variable reads
the fan speed offset value in
%PWM for Medium Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value using
index value 2
Values from 0-100
racadm get
system.thermalsettin
gs
FanSpeedMediumOffset
Val
This returns a value such as
“47”. This means that when you
use the following command, it
applies a fan speed offset of
Medium (47% PWM) over
baseline fan speed
racadm set
system.thermalsettin
gs FanSpeedOffset 2
FanSpeedOffset
Using this object with get
command displays the
existing Fan Speed Offset
value.
Using this object with set
command allows setting the
required fan speed offset
value.
The index value decides the
offset that is applied and the
FanSpeedLowOffsetVal
,
FanSpeedMaxOffsetVal
,
FanSpeedHighOffsetVa
l, and
FanSpeedMediumOffset
Val objects (defined earlier)
are the values at which the
offsets are applied.
Values are:
0 — Low Fan Speed
1 — High Fan Speed
2 — Medium Fan Speed
3 — Max Fan Speed
255 — None
To view the existing setting:
racadm get
system.thermalsettin
gs.FanSpeedOffset
To set the fan speed offset to
High value (as defined in
FanSpeedHighOffsetVal)
racadm set
system.thermalsettin
gs.FanSpeedOffset 1
MFSMaximumLimit
Read Maximum limit for MFS
Values from 1 — 100 To display the highest value that
can be set using
MinimumFanSpeed option:
racadm get
system.thermalsettin
gs.MFSMaximumLimit
54 Setting up managed system and management station