Users Guide
Table 8. Thermal Settings (continued)
Object Description Usage Example
Make sure to specify the value
depending on the type of object.
For more information, see
RACADM help.
To set the limit to the default
value:
racadm set
system.thermalsettin
gs.AirExhaustTemp
255
FanSpeedHighOffsetVal
• Getting this variable reads
the fan speed offset value in
%PWM for High Fan Speed
Offset setting.
• This value depends on the
system.
• Use FanSpeedOffset
object to set this value using
index value 1.
Values from 0-100
racadm get
system.thermalsettin
gs
FanSpeedHighOffsetVa
l
A numerical value, for example
66, is returned. This value
indicates that when you use the
following command, it applies a
fan speed offset of High (66%
PWM) over the baseline fan
speed
racadm set
system.thermalsettin
gs FanSpeedOffset 1
FanSpeedLowOffsetVal
• Getting this variable reads
the fan speed offset value in
%PWM for Low Fan Speed
Offset setting.
• This value depends on the
system.
• Use FanSpeedOffset
object to set this value using
index value 0.
Values from 0-100
racadm get
system.thermalsettin
gs
FanSpeedLowOffsetVal
This returns a value such as
“23”. This means that when you
use the following command, it
applies a fan speed offset of
Low (23% PWM) over baseline
fan speed
racadm set
system.thermalsettin
gs FanSpeedOffset 0
FanSpeedMaxOffsetVal
• Getting this variable reads
the fan speed offset value in
%PWM for Max Fan Speed
Offset setting.
• This value depends on the
system.
• Use FanSpeedOffset to
set this value using index
value 3
Values from 0-100
racadm get
system.thermalsettin
gs
FanSpeedMaxOffsetVal
This returns a value such as
“100”. This means that when
you use the following command,
it applies a fan speed offset of
Max (meaning full speed, 100%
PWM). Usually, this offset
Setting up managed system and management station 53