Item 3:
Description:
On Dell 13th generation PowerEdge servers with PERC 830, create 98 foreign drive on it, then Login to iDRAC GUI,
under Storage -> Controller page -> Setup Tab, selecting PERC 830 Controller from the drop down box, Foreign
configuration section shows "STOR006: Unable to complete the operation."
Resolution:
Press Ctrl+R or in-band agent like OMSS can be used to preview foreign configuration. Issue is seen only with Preview,
actual foreign configuration import through racadm will work.
Versions/Systems affected: PowerEdge R630
Dell tracking: JIT-12251
Item 4:
Description:
On NANO operating system, you cannot install a firmware or driver DUP if it is in .exe format.
Versions/Systems affected: All
Item 5:
Description:
Deployment of the Windows server operating systems (OS) using Lifecycle
Controller (LC) may fail with one of the following message:
- Windows installation cannot continue because a required driver could not be installed.
- Product key required.
- Windows cannot find the software license terms.
This happens when the Windows setup copies the drivers to the scratch space (X: drive) and the scratch space
becomes full.
Resolution:
To resolve this issue, do any of the following:
Remove all the installed add-on devices before starting the OS installation.
After the OS installation is complete, connect the add-on devices and manually install the remaining drivers using Dell
Update Packages (DUPs).
To avoid physically removing the hardware, disable the PCIe slots in the BIOS.
Increase scratch space size beyond 32 MB using DISM set-scratchspace command when creating customized
deployment. See http://technet.microsoft.com/en-us/library/dd799261(v=ws.10).aspx for more details.
Versions/Systems affected: This issue may occur on 12th and 13th generation Dell PowerEdge servers.
Item 6:
Description:
The SSM task header displays RAID-Update for both RAID and non-RAID updates.
Resolution:
No action is required.
Versions/Systems affected: All