Release Notes

BOOTPROTO=dhcp
ONBOOT=yes
o After you complete the steps above, you can get the specific interface up by using the ifup idrac
command.
Note: Ensure that you perform these steps if you do not see ifcfg-idrac config file on reboots.
Dell PowerEdge C6320p chassis has a 24 slot backplane that is shared between four compute nodes in the
chassis. Each compute node has one 1.8-inch internal SATA drive and is also connected to six drives in the
backplane. Each compute node enumerates these 7 drives and, in the current release, these seven drives are
always mapped to slot 0 through 6, where slot 0 is for the internal SATA drive and slots 1-6 are for the six
drives in the backplane. Therefore, the drives in backplane physical slots 7 through 24 also get enumerated as
slot 1-6 on each compute node as:
BIOS SATA Port A (Internal HDD) Disk.Direct.0-0: AHCI.Embedded.1-1
BIOS SATA Port B (Front Panel HDD) Disk.Direct.0-1: AHCI.Embedded.2-1
BIOS SATA Port C (Front Panel HDD) Disk.Direct.1-2: AHCI.Embedded.2-1
BIOS SATA Port D (Front Panel HDD) Disk.Direct.2-3: AHCI.Embedded.2-1
BIOS SATA Port E (Front Panel HDD) Disk.Direct.3-4: AHCI.Embedded.2-1
BIOS SATA Port F (Front Panel HDD) Disk.Direct.4-5: AHCI.Embedded.2-1
BIOS SATA Port G (Front Panel HDD) Disk.Direct.5-6: AHCI.Embedded.2-1
Using local RACADM, the command racadm eventfilters get -c idrac.alert.all may not list all available event
filter configuration. If it fails, use firmware RACADM or remote RACADM to execute the command.
Limitations
Item 1:
Description:
On the Dell 13th generation PowerEdge servers, a clone export of a system with 64 virtual disks does not recreate the
virtual disks on the target system.
Resolution
On Clone or Replace modes of Configuration XML export, the virtual disk creation operation is set to "CreateAuto" by
default. Change the operation to "Create" and specify the physical disks to be used by FQDD to resolve this issue.
Versions/Systems affected: All Dell PowerEdge systems with iDRAC8.
Dell tracking: JIT-28891
Item 2:
Description:
For Intel cards, the PHY link on the shared LOM ports stays up during a DC power cycle.
Resolution:
The NIC can only be reset by doing an AC power cycle
Versions/Systems affected: PowerEdge R730
Dell tracking: JIT-30630