Issue 110977:
Description
When IO Identity Optimization is enabled and you configure the Virtual Addresses, Storage Initiator, and Target
settings, the job runs correctly. However, ConfigResults do not list the change set.
Resolution
Refer the Lifecycle Controller logs.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 236311:
Description
Persistence policy is not supported on ChassisSlot NIC devices.
Resolution
Reconfigure or clear the Virtual, Storage Initiator, or Target settings manually.
Version/Systems Affected
All PowerEdge blade servers on PowerEdge FX2 with iDRAC8.
Issue 206438:
Description
The possible values for the WS-MAN IOI Persistence attributes are confusing to understand.
Example:
PossibleValues = None, WarmReset, ColdReset, WarmReset, ColdReset, ACPowerLoss, WarmReset, ACPowerLoss,
ColdReset, ACPowerLoss, WarmReset, ColdReset, ACPowerLoss
Resolution
Add the –format:pretty option in the WinRM command to display the output in an understandable format
Example:
<n1:PossibleValues>None</n1:PossibleValues>
<n1:PossibleValues>WarmReset</n1:PossibleValues>
<n1:PossibleValues>ColdReset</n1:PossibleValues>
<n1:PossibleValues>WarmReset, ColdReset</n1:PossibleValues>
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 238583:
Description
On systems with iDRAC8, non-root user privileges are lost after installing and uninstalling a personality module.
Resolution
Login using root credentials and modify the non-root users or reset iDRAC configurations to the default setting.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 203881:
Description
iDRAC interfaces report the battery status as Degraded instead of Battery Missing when the battery is unplugged and
Battery High Temp when the battery temperature exceeds 70°C.