Release Notes

Issue 233773:
Description
After applying the Boot Identity profile on the PowerEdge M630 blade server with DX69G NDC card on port 1, the
WWN/MAC page displays the MAC Addresses under the Flexaddress tab only instead of displaying in Remote
assigned MAC Address tab.
Resolution
None.
Versions/Systems Affected
Dell PowerEdge M1000e systems
Issue 253227:
Description
Occasionally, after changing NIC Selection, you may not be able to set NIC Failover.
Resolution
Reboot iDRAC or perform an AC power cycle to clear the issue.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8 2.21.21.21
Issue 262334:
Description
While configuring the iSCSI parameters on any Emulex adapter using an XML import and with IO Identity
Optimization set to enabled, the configuration of the FirstTgtIscsiName attribute fails if the length of the configured
strings is greater than 152 characters.
Resolution
Disable IO Identity Optimization and run the same job or ensure that the length of the string for the FirstTgtIscsiName
is less than 152 characters.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and Emulex adapters supporting iSCSI.
Issue 260802:
Description
If the physical drive firmware is updated using the operating system DUP, the updated firmware version is not
displayed on the iDRAC interfaces.
Resolution
Perform a host power cycle or run the racreset RACADM command.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 260633:
Description
Deleting multiple virtual disks in a single real-time configuration job fails.
Resolution
Delete one virtual disk at a time.
Versions/Systems Affected
All 13th generation Dell PowerEdge systems with iDRAC8 and PERCH830 adapter.