Issue 58:
Description
SNMP Agent Default Community Name (public). [Nessus]
Resolution
iDRAC provides limited read-only information to third-party tools for identification purposes only. The SNMP Agent
is enabled by default and uses the default SNMP community name. The SNMP Agent can be disabled or SNMP
community name can be changed if not using 3rd party tools.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 59:
Description
SSL Certificate - Self-Signed Certificate. [Qualysguard, Nesssus, Rapid7, Retina].
Resolution
iDRAC default SSL Certificate is self-signed by iDRAC. Upload a 3rd party or in-house CA signed SSL certificate.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 60:
Description
While setting the value for uefidevicepath by using RACADM interface, the value displayed in the iDRAC GUI
and virtual console is BIOS Setup instead of FirstBootDevice. However, the correct value is displayed on
interfaces such as Redfish, RACADM, and WS-MAN.
Resolution
None
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 61:
Description
On systems where uefidevicepath is not supported by the BIOS, if you set the firstbootdevice value to
uefidevicepath, you may notice that the BIOS reboots normally during a host reboot and the firstbootvalue
is set to Normal after a reboot.
Resolution
None
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 110977:
Description
When IO Identity Optimization is enabled and you configure the Virtual Addresses, Storage Initiator, and Target
settings, the job runs correctly. However, ConfigResults do not list the change set.
Resolution
Refer the Lifecycle Controller logs.