Release Notes
Issue 48:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 49:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update using the
iDRAC GUI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 50:
Description
The BIOS configuration job completes with errors when Virtualization Technology is set to Enabled or Disabled. All
the settings are successfully applied, however, the job status displays an error.
Resolution
None.
Versions/ Systems Affected
All PowerEdge systems with iDRAC8.
Issue 51:
Description
On the Dell 12th generation PowerEdge servers flashed with iDRAC8, firmware update and configuration operations
including secure erase for Samsung NVMe PCIe SSDs using iDRAC interfaces, do not work. Even though you can
start these tasks using iDRAC interfaces, the tasks will eventually fail.
Resolution
Use other methods of firmware update and configuration using the operating system.
Versions/ Systems Affected
Dell 12th generation PowerEdge systems with iDRAC8.
Issue 52:
Description
Creating T10 PI capable virtual disks using T10 PI capable disk-drives from iDRAC GUI fails.
Resolution
Use RACADM, WS-MAN, or OMSS to create virtual disks with T10 PI capability.
Versions/ Systems Affected