Release Notes
• On the Lifecycle Controller Home page, click System Setup, and then click Advanced Hardware
Configuration.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers
Issue 5:
Description
After you successfully update the firmware of a CPLD on a modular server, and then perform a firmware update
operation of a component that requires a system restart (such as BIOS), the server is automatically and repeatedly
restarted.
Resolution
Perform a Power Cycle operation on the server.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 6:
Description
Lifecycle Controller may go into an infinite loop when a network operation is tried with an incorrect NFS share name.
Resolution
Restart Lifecycle Controller and retry the operation with the correct NFS share name details.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 7:
Description
On the Dell 12th generation of PowerEdge servers, while deploying the operating system by selecting the UEFI boot
mode, an error message is displayed when you click Finish. This error occurs if you try to connect the optical drive or
virtual media after you launch Lifecycle Controller.
Resolution
Reboot the server and ensure that you connect the optical drive or virtual media before launching Lifecycle Controller.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 8:
Description
If NPAR is enabled, Lifecycle Controller might show unexpected behavior when configuring network settings.
Resolution
Disable the NAPR option and execute the network setting configurations. To disable the NAPR option, go to System
Setup-> Device Setting.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 9:
Description
The process of retrieving IPv6 address from the DHCP server with VLAN connection takes a few minutes.