Release Notes

Resolution:
None.
Versions/Systems Affected:
Dell PowerEdge M1000e systems.
Issue 232183:
Description
MAC Address is displayed in the iDRAC GUI for Intel 8F6NV Card, instead of Flex Address MAC only on
WWN/MAC page.
Resolution
None
Versions/Systems Affected
Dell PowerEdge M1000e systems
Issue 233773:
Description
After applying the Boot Identity profile on the PowerEDge M630 blade server with DX69G NDC card on port 1, the
WWN/MAC page displays the MAC Addresses under the Flexaddress tab only instead of displaying in Remote
assigned MAC Address tab.
Resolution
None.
Versions/Systems Affected
Dell PowerEdge M1000e systems
Issue 237790
Description
On a 12th generation of PowerEdge server with iDRAC 7, the firmware version displays iDRAC8 instead of iDRAC7.
Resolution
None.
Versions/Systems Affected
Dell 12th generation of PowerEdge server with iDRAC7
Issue 244737
Description
DeletVD from CTR-R using warm reboot causes further VD create failure (using iDRAC interfaces through realtime
job) on same physical disks on maxconfig.
Resolution
Perform a power cycle or run the racreset command.
Versions/Systems Affected
All PowerEdge servers that have max configs with more than 2 controllers, greater than 5 enclosures, and over 100+
disks.