Release Notes

Issue 206438:
Description
The possible values for the WS-MAN IOI Persistence attributes are confusing to understand.
Example:
PossibleValues = None, WarmReset, ColdReset, WarmReset, ColdReset, ACPowerLoss, WarmReset, ACPowerLoss,
ColdReset, ACPowerLoss, WarmReset, ColdReset, ACPowerLoss
Resolution
Add the format:pretty option in the WinRM command to display the output in an understandable format
Example:
<n1:PossibleValues>None</n1:PossibleValues>
<n1:PossibleValues>WarmReset</n1:PossibleValues>
<n1:PossibleValues>ColdReset</n1:PossibleValues>
<n1:PossibleValues>WarmReset, ColdReset</n1:PossibleValues>
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 238583:
Description
On systems with iDRAC8, non-root user privileges are lost after installing and uninstalling a personality module.
Resolution
Login using root credentials and modify the non-root users or reset iDRAC configurations to the default setting.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 203881:
Description
iDRAC interfaces report the battery status as Degraded instead of Battery Missing when the battery is unplugged and
Battery High Temp when the battery temperature exceeds 70°C.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and iDRAC8 (PERC8 and PERC9).
Issue 171960:
Description
Lifecycle Controller firmware is inaccessible after a performing hardware diagnostic and rebooting the system. This
issue is captured in the Lifecycle Controller log.
Resolution
Reboot the system again to start Lifecycle Controller.
Versions/Systems Affected
Dell 13th generation of PowerEdge systems with iDRAC8.