Release Notes
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 51:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 52:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 53:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update using the
iDRAC GUI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 54:
Description
When the threshold value is set to zero degrees, Lifecycle Controller or SEL log may display an Inlet Temperature
value that is lower than the critical or warning threshold value and the LED may glow amber.
Resolution
None.
Versions/ Systems Affected
Dell PowerEdge C6320 systems with iDRAC8.
Issue 55:
Description
Lifecycle log may display an iDRAC service module communication with iDRAC has ended
warning message.
Resolution
None.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.