Release Notes
Note: It does not occur with Virtual Media in the detached state. It also does not occur without the SIP and with Virtual
Media in the detached from iDRAC8.
Resolution
Retry the operation.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 3:
Description
Some of the supported components are not displayed on the Firmware Update-> View Current Versions page.
Resolution
Restart the server and open View Current Versions page.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 4:
Description
If a Mellanox card is present in the system, then under Network Settings, the port number must be displayed as Port 1
and Port 2, because it is a dual port. But, the port number is displayed as Port 1 for both the ports or the port numbers
are not displayed.
Resolution
To distinguish between the port numbers, see the MAC address or the Device Settings.
You can access Device Settings in the following methods:
• During POST, press <F2>, and then click System Setup.
• On the Lifecycle Controller Home page, click System Setup, and then click Advanced Hardware
Configuration.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers
Issue 5:
Description
Lifecycle Controller may go into an infinite loop when a network operation is tried with an incorrect NFS share name.
Resolution
Restart Lifecycle Controller and retry the operation with the correct NFS share name details.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.
Issue 6:
Description
Intel I350 Gigabit embedded network firmware cannot be updated using the LC GUI or any other interfaces using LC-
RS.
Resolution
Update the firmware using the Windows (.exe) or Linux (.bin) executable formats.
Versions/Systems Affected
All LC–supported Dell PowerEdge servers.