Release Notes

Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 51:
Description
The Enumeration filter commands fail for certain filters.
Resolution
Use Enumeration or Get Instance call to view the same data. The required properties can be filtered by the consoles.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 52:
Description
While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query
does not return any result.
Resolution
The maximum number of properties that can be included in a WQL/CQL query using WS-MAN is 7. Perform the
filtering on the client system or make multiple calls each having not more than 7 properties.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 53:
Description
Scheduling an automatic update using the iDRAC GUI fails in case CSIOR is set to disabled.
Resolution
Use RACADM to schedule an automatic update job with CSIOR disabled or enable CSIOR and update using the
iDRAC GUI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
iDRAC - Limitations
If floppy emulation is enabled when a bootable USB key is mounted as a Virtual Media from the Virtual
Console and if you try to delete any file from the mounted USB key (floppy), the blue screen appears
immediately.
Web server session time-out is not exact. It is either 10% more or 15 seconds more, whichever is greater.
WinRM and RACADM commands may become unresponsive during BIOS update or when setting BIOS,
NIC, or RAID attributes through Lifecycle Controller.
If invalid credentials are used for the maximum login attempts, the IP is blocked for the duration of the IP
Blocking Penalty Time and a message is not displayed.
If Internet Explorer (IE) 64-bit browser is used to log in to iDRAC8 Web interface and when viewing the
power usage graph, the X and Y axis labels appear too small to read. This is a known limitation for IE 64-bit
only. The labels appear correctly in IE 32-bit browser.
On Linux management stations, if Firefox is launched from the root user, a USB key is mapped in Virtual
Media successfully. If Firefox is launched from any user other than the root user, a USB key is not shown for
mapping because the user must have root privileges to access all the low-level drives.
Alert notification for battery events does not work.
Operating system information on the System Summary page does not display after rebooting iDRAC8 until
the operating system is rebooted.
iDRAC8 users with user names containing a semi-colon (;) cannot log in to iDRAC8 through SSH.