Issue 32:
Description
In the iDRAC web interface, the following storage pending operations status is not displayed in Pending Operations
pop-up message and Storage->Pending Operations page:
• Virtual Disk(s) - Encrypt operations.
• Controller(s) - Create, Modify, or Delete security key operations.
• Controller(s) - Import or Clear Foreign Configuration operations.
• PCIe SSD(s) - Secure Erase or Prepare to Remove operations.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 33:
Description
When a passive backplane (that is not connected to PERC) is updated from the operating system, the System Inventory
page in the iDRAC web interface does not display the updated version.
Resolution
Reset iDRAC using racadm racreset command.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 34:
Description
If you log in to the iDRAC8 web interface with Login and Config iDRAC privilege, then on the Update and Rollback
page, an additional Firmware Settings submenu appears.
Resolution
None
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 35:
Description
On the Network Devices page, the Initiator and Storage Target Settings table overflows to the right if you set the
initiator name and chap ID value with more than 120 characters.
Resolution
Reduce the zoom level or use the scrollbar to view the entire data.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 36:
Description
URL string in iDRAC hardware inventory list displays incorrect https port number.