Release Notes

Issue 22:
Description
If the PERC controllers have global hot spare assigned and a virtual disk is deleted, the physical disk configured as
global hot spare is not reported as hot spare through the iDRAC interface. However, the physical disk continues to
function as a global hot spare.
Resolution
Reset DRAC or power cycle the host system.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 23:
Description
The foreign configuration preview (through iDRAC Web interface) may not contain data about foreign drives under
some scenarios (example, the foreign configuration is incomplete or foreign virtual disk is in a failed state).
Resolution
Navigate to the Storage > Physical Disks page to view the physical disks that are foreign.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 24:
Description
In the Safari browser, if the iDRAC web session times out; clicking the Virtual Console and logging out of the GUI
page does not work.
Resolution
Instead of Virtual Console menu, choose other options like logout or other menu options, or use GUI refresh or
Browser refresh option to logout.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 25:
Description
After updating the firmware on an enclosure connected to a 12Gbps SAS Controller, the updated firmware version is
not displayed in the inventory or through any of the interfaces (iDRAC GUI, RACADM) until the server is powered off
and then powered back on.
Resolution
Power the server off then power it on. The updated firmware version is displayed.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 26:
Description
Updating multiple iDRAC DUP using the web interface is not successful when the total size of the DUPs exceeds 300
MB.
Resolution
Make sure the total size is less than 300 MB and then perform an update.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.