Reference Guide
Examples To set the minimum noncritical threshold level for a power
sensor type.
racadm sensorsettings set iDRAC.Embedded.
1#SystemBoardCPUUsage -level Max 95
NOTE: The entered value must be lesser or higher than the
sensor critical threshold limit.
serveraction
Descripti
on
Enables you to perform power management operations on the
host system.
To run this subcommand, you must have the Execute Server
Control Commands permission.
Synopsis
racadm serveraction <action> -f
Input
<action> — Specifies the power management operation to
perform. The options are:
• hardreset — Performs a force reset (reboot) operation on
the managed system.
• powercycle — Performs a power-cycle operation on the
managed system. This action is similar to pressing the power
button on the system’s front panel to turn off and then turn
on the system.
• powerdown — Powers down the managed system.
• powerup — Powers up the managed system.
• powerstatus — Displays the current power status of the
server (ON or OFF).
• graceshutdown — Performs a graceful shutdown of the
server. If the operating system on the server cannot shut
down completely, then this operation is not performed.
• -f — Force the server power management operation.
This option is applicable only for the PowerEdge-VRTX
platform. It is used with powerdown,powercycle, and
hardreset options.
NOTE: The actionpowerstatus is not allowed with -a
option.
Output Displays an error message if the requested operation is not
completed, or a success message if the operation is completed.
97