Reference Guide

-f— Specifies the FTP server IP address or FQDN, username,
and password used for firmware image. Applies FTP
download process for firmware update.
--clearcfg (Optional) — After the firmware update, this
option removes the previous iDRAC configuration.
CMC version 3.00 accepts IPv4, IPv6 or fully qualified
domain names (FQDN) for both FTP and TFTP servers.
Output
Displays a message indicating the operation that is being
performed.
Example
Update firmware on servers of iDRAC generation.
racadm fwupdate -g -u -a 192.168.0.100 -d
firmimg.d7
Download firmware update file from a specified location on
the TFTP server at a specific IP address.
racadm fwupdate -g -u -a 143.166.154.143 -d
<path>
After the image file is downloaded from the TFTP server, the
update process begins. When completed, iDRAC is reset.
Read the status of the firmware update.
racadm fwupdate -s
To block the firmware downgrade on 3000W AC power
supply configuration.
racadm fwupdate –s
Ready for firmware update
racadm fwupdate –g –u –a 10.210.138.121 –d
firming-4.40-A00.cmc –m cmc-active
Firmware update has been initiated. This
update process may take several minutes to
complete.
racadm fwupdate –s
Cannot update local CMC firmware: The
uploaded firmware image does not support the
installed power supplies.
NOTE: Firmware update from local RACADM (using -p -u
-d
options) is not supported on linux OS.
The following table describes the firmware update method supported for
each interface.
44