Reference Guide

The following section provides information about the objects in this group.
NOTE: For Dell PowerEdge FM120x4 server with more than one iDRAC,
the power is received and shared from CMC. Hence, the information
about power and temperature for individual iDRACs are not displayed.
System.Power.Status (Read Only)
Descripti
on
Represents the device power state, either ON or OFF.
Legal
Values
0 — Server is off
1 — Server is on.
Default
Value
0 — Server is off
Write
Privilege
Not Applicable
License
Required
Not Applicable
Depende
ncy
Not Applicable
System.Power.ServerAllocation (Read Only)
Descripti
on
Indicates the power allocated to running blades. This value is
displayed in both watts and BTU/h units.
Legal
Values
0–7928
Default
Value
Not Applicable
Write
Privilege
Not Applicable
License
Required
Not Applicable
Depende
ncy
None
263