Reference Guide
cfgRhostsSmtpServerIpAddr (Read or Write)
Descripti
on
The IPv4 or IPv6 address of the network SMTP server.
The SMTP server transmits email alerts from iDRAC if the alerts
are configured and enabled.
Legal
Values
A string representing a valid SMTP server IPv4 or IPv6 address.
For example: 192.168.0.55.
Default
For IPv4, it is 0.0.0.0
cfgRhostsSyslogEnable (Read or Write)
Descripti
on
To allow the RAC and SEL logs to be written to up to three
remote syslog servers Enables or disables remote syslog.
Legal
Values
• 1 (TRUE)
• 0 (FALSE)
Default 0
cfgRhostsSyslogPort (Read or Write)
Descripti
on
Remote syslog port number to use for writing the RAC and SEL
logs to a remote syslog server.
Legal
Values
10–65535
Default 514
cfgRhostsSyslogServer1 (Read or Write)
Descripti
on
To store the RAC and SEL logs specify the first of three possible
remote syslog servers. This property is only valid if
cfgRhostsSyslogEnable is set to 1 (enabled).
Legal
Values
String from 0 to 63 characters.
Default
<blank>
159