Reference Guide

DriverVersion = Information Not
Available
RebuildRate = 45
BgiRate = 13
CheckConsistencyRate = 18
ReconstructRate = 12
PatrolReadRate = 21
PatrolReadMode = Disabled
PatrolReadState = Stopped
CheckConsistencyMode = Normal
LoadBalanceSetting = Disabled
CopybackMode = OFF
PreservedCache = Not Present
CacheMemorySize = 2048 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Security Key
Assigned
EncryptionMode = Supported with
LKM
SasAddress =
0x5B8CA3A0F3073700
PciDeviceId = 0x5d
PciSubdeviceId = 0x1f47
PciVendorId = 0x1000
PciSubvendorId = 0x1028
PciBus = 0x3
PciDevice = 0x0
PciFunction = 0x0
BusWidth = Unknown
SlotLength = Unknown
SlotType = Unknown
MaxCapableSpeed = 12.0 Gb/s
LearnMode = Not supported
T10PICapability = Capable
SupportRAID10UnevenSpans = Supported
SupportEnhancedAutoForeignImport = Supported
EnhancedAutoImportForeignConfig = Enabled
SupportControllerBootMode = Supported
ControllerBootMode = Continue Boot
On Error
RealtimeConfigurationCapability = Capable
CurrentControllerMode = RAID
This command displays the filtered property values for all returned
controller objects.
racadm storage get controllers -o -p Name
RAID.Integrated.1-1
Name = PERC H710P Adapter (Embedded)