Reference Guide

-speed — specifies the initialization of the Virtual disk.
fast— performs fast initialization.
full— performs slow initialization.
blink: <FQDD> or unblink: <FQDD><FQDD> can be
physical disk drives or virtual disks.
<PCIeSSD FQDD> — specifies the PCIeSSD FQDD.
<PCIeSSD controller|enclosure FQDD> — specifies
the PCIeSSD controller or enclosure FQDD.
preparetoremove — specifies the PCIeSSD drive to prepare
for removal.
NOTE: Make sure that ISM is installed and running to
perform preparetoremove operation.
secureerase— specifies the PCIeSSD drive to perform
secure erase.
Example
To generate and view information about the inventory of controllers,
virtual disks, storage enclosures, and physical disk drives.
To generate and view information about the inventory of storage root
node.
This command retrieves the status.
racadm storage get status
raid Root Node Status : Ok
To generate and view information about the inventory of controllers
connected to the server.
racadm storage get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller
objects along with their keys.
racadm storage get controllers -o
RAID.Integrated.1-1
Status = Ok
DeviceDescription = Integrated RAID
Controller 1
RollupStatus = Ok
Name = PERC H730P Mini
(Embedded)
FirmwareVersion = 25.2.1.0025
117