Reference Guide
• -speed — specifies the initialization of the Virtual disk.
– fast— performs fast initialization.
– full— performs slow initialization.
• blink: <FQDD> or unblink: <FQDD> — <FQDD> can be
physical disk drives or virtual disks.
• <PCIeSSD FQDD> — specifies the PCIeSSD FQDD.
• <PCIeSSD controller|enclosure FQDD> — specifies
the PCIeSSD controller or enclosure FQDD.
• preparetoremove — specifies the PCIeSSD drive to prepare
for removal.
NOTE: Make sure that ISM is installed and running to
perform preparetoremove operation.
• secureerase— specifies the PCIeSSD drive to perform
secure erase.
Example
• To generate and view information about the inventory of controllers,
virtual disks, storage enclosures, and physical disk drives.
– To generate and view information about the inventory of storage root
node.
This command retrieves the status.
racadm storage get status
raid Root Node Status : Ok
– To generate and view information about the inventory of controllers
connected to the server.
racadm storage get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller
objects along with their keys.
racadm storage get controllers -o
RAID.Integrated.1-1
Status = Ok
DeviceDescription = Integrated RAID
Controller 1
RollupStatus = Ok
Name = PERC H730P Mini
(Embedded)
FirmwareVersion = 25.2.1.0025
117