Reference Guide

To start or stop a blink or identify operation on the specified
or PCIeSSD device.
racadm storage blink:<FQDD>
racadm storage blink:<PCIeSSD FQDD>
racadm storage unblink:<FQDD>
racadm storage unblink:<PCIeSSD FQDD>
To prepare the PCIeSSD drive for removal.
racadm storage preparetoremove <PCIeSSD FQDD>
To perform a secure erase on PCIeSSD device.
racadm storage secureerase:<PCIeSSD FQDD>
NOTE: You can also run the command using raid in place
of storage.
Input
-o — Specifies the optimized version.
-p — Specifies the property name.
--refkey — Specifies the controller or enclosure FQDDs.
-rl — Sets the storage level.
r0 — storage 0-Striping
r1 — storage 1-Mirroring
r5 — storage 5-Striping with Parity
r6 — storage 6-Striping with Extra Parity
r10 — storage 10-Spanned Striping with Mirroring
r50 — storage 50-Spanned Striping with Parity
r60 — storage 60-Spanned Striping with Extra Parity
-wp{wt|wb|wbf} — Sets the write policy to Write Through,
Write Back, or Write Back Force
-rp {nra|ra|ara} — Sets the read policy to No Read
Ahead, Read Ahead, Adaptive Read Ahead
-ss — Specifies the stripe size to use.
-pdkey:<PD FQDD list> — Specifies the physical disk
drive to use in the virtual disk.
-dcp — Sets the Disk Cache Policy in the Virtual Disk.
enabled — Allows the virtual disk to use the cache.
disabled — Does not allow the virtual disk to use the
cache.
default — Uses the default cache policy. For SAS drives,
use the disabled option and for SATA drives, use the
enabled option by default.
115