Removable Flash Media Provides information about the Internal SD ModulesvFlash and Internal Dual SD Module
(IDSDM).
When IDSDM redundancy is enabled, the following IDSDM sensor status is displayedIDSDM Redundancy Status,
IDSDM SD1, IDSDM SD2. When redundancy is disabled, only IDSDM SD1 is displayed.
If IDSDM redundancy is initially disabled when the system is powered on or after an iDRAC reset, the IDSDM SD1 sensor
status is displayed only after a card is inserted.
If IDSDM redundancy is enabled with two SD cards present in the IDSDM, and the status of one SD card is online while
the status of the other card is offline. A system reboot is required to restore redundancy between the two SD cards in
the IDSDM. After the redundancy is restored, the status of both the SD cards in the IDSDM is online.
During the rebuilding operation to restore redundancy between two SD cards present in the IDSDM, the IDSDM status is
not displayed since the IDSDM sensors are powered off.
NOTE: If the host system is rebooted during IDSDM rebuild operation, the iDRAC does not display the IDSDM
information. To resolve this, rebuild IDSDM again or reset the iDRAC.
System Event Logs (SEL) for a write-protected or corrupt SD card in the IDSDM module are not repeated until they are
cleared by replacing the SD card with a writable or good SD card, respectively.
Temperature Provides information about the system board inlet temperature and exhaust temperature (only applies to
rack servers). The temperature probe indicates whether the status of the probe is within the pre-set warning and critical
threshold value.
Voltage Indicates the status and reading of the voltage sensors on various system components.
The following table provides how to view the sensor information using iDRAC Web interface and RACADM. For information
about the properties that are displayed on the Web interface, see the iDRAC Online Help for the respective pages.
Table 9. Sensor Information Using Web Interface and RACADM
View Sensor Information For Using Web Interface Using RACADM
Batteries Overview > Hardware > Batteries Use the getsensorinfo command.
For power supplies, you can also use the
System.Power.Supply command with
the get subcommand.
For more information, see the iDRAC8
RACADM Command Line Interface
Reference Guide available at dell.com/
support/manuals.
Fan Overview > Hardware > Fans
CPU Overview > Hardware > CPU
Memory Overview > Hardware > Memory
Intrusion Overview > Server > Intrusion
Power Supplies Overview > Hardware > Power
Supplies
Removable Flash Media Overview > Hardware > Removable
Flash Media
Temperature Overview > Server > Power/Thermal
> Temperatures
Voltage Overview > Server > Power/Thermal
> Voltages
92 Viewing iDRAC and Managed System Information