Run the service.msc command. In the list of services displayed, see if there is a service called DSM iDRAC Service
Module.
On Linux:
Run the command /etc/init.d/dcismeng status. If the iDRAC Service Module is installed and running, the status
displayed is running.
NOTE: Use the systemctl status dcismeng.service command instead of the init.d command to check if the
iDRAC Service Module is installed on RedHat Enterprise Linux 7 operating system.
How to check the version number of the iDRAC Service Module installed in the system?
To check the version of the iDRAC Service Module in the system, do any of the following:
Click Start > Control Panel > Programs and Features. The version of the installed iDRAC Service Module is listed in the
Version tab.
Go to My Computer > Uninstall or change a program.
What is the minimum permission level required to install the iDRAC Service Module?
To install the iDRAC Service Module, you must have administrator level privileges.
While installing the iDRAC Service Module, it displays an error message This is not a supported server. Consult the
User Guide for additional information about the supported servers. How to resolve this?
Before installing the iDRAC Service Module, make sure that the server is a 12th generation PowerEdge sever or later. Also, make
sure that you have a 64-bit system.
The following message is displayed in the OS log, even when the OS to iDRAC Pass-through over USBNIC is
configured properly. Why?
The iDRAC Service Module is unable to communicate with iDRAC using the OS to iDRAC Pass-
through channel
iDRAC Service Module uses the OS to iDRAC pass-through over USB NIC feature to establish the communication with iDRAC.
Sometimes, the communication is not established though the USB NIC interface is configured with the correct IP endpoints.
This may happen when the host operating system routing table has multiple entries for the same destination mask and the USB
NIC destination is not listed as the first one in routing order.
Destination
Gateway Genmask Flags Metric Ref Use Iface
default 10.94.148.1 0.0.0.0 UG 1024 0 0 em1
10.94.148.0 0.0.0.0 255.255.255.0 U 0 0 0 em1
link-local 0.0.0.0 255.255.255.0 U 0 0 0 em1
link-local 0.0.0.0 255.255.255.0 U 0 0 0 enp0s20u12u3
In the example enp0s20u12u3 is the USB NIC interface. The link-local destination mask is repeated and the USB NIC is not
the first one in the order. This results in the connectivity issue between iDRAC Service Module and iDRAC over the OS to
iDRAC Pass-through. To troubleshoot the connectivity issue, make sure that the iDRAC USBNIC IPv4 address (by default it is
169.254.0.1) is reachable from the host operating system.
If not:
Change the iDRAC USBNIC address on a unique destination mask.
Delete the entries that are not required from the routing table to make sure that USB NIC is chosen by route when the host
wants to reach the iDRAC USB NIC IPv4 address.
When uninstalling iDRAC Service Module from a VMware ESXi server, the virtual switch is named as
vSwitchiDRACvusb and port group as iDRAC Network on the Vsphere client. How to delete them?
While installing iDRAC Service Module VIB on a VMware ESXi server, iDRAC Service Module creates the vSwtich and Portgroup
to communicate with iDRAC over the OS to iDRAC Pass-through in USB NIC mode. After the uninstallation, the virtual switch
vSwitchiDRACvusb and the port group iDRAC Network are not deleted. To delete it manually, perform one of the following
steps:
Go to vSphere Client Configuration wizard and delete the entries.
Go to the Esxcli and type the following commands:
To remove port group: esxcfg-vmknic -d -p "iDRAC Network"
To remove vSwitch: esxcfg-vswitch -d vSwitchiDRACvusb