Users Guide

Table Of Contents
To maximize Virtual Media performance, launch the Virtual Media with the Virtual Console disabled or do one of the following:
Change the performance slider to Maximum Speed.
Disable encryption for both Virtual Media and Virtual Console.
NOTE: In this case, the data transfer between managed server and iDRAC for Virtual Media and Virtual Console will not
be secured.
If you are using any Windows server operating systems, stop the Windows service named Windows Event Collector. To do
this, go to Start > Administrative Tools > Services. Right-click Windows Event Collector and click Stop.
While viewing the contents of a floppy drive or USB key, a connection failure message is displayed if the same drive
is attached through the virtual media?
Simultaneous access to virtual floppy drives are not allowed. Close the application used to view the drive contents before
attempting to virtualize the drive.
What file system types are supported on the Virtual Floppy Drive?
The virtual floppy drive supports FAT16 or FAT32 file systems.
Why is an error message displayed when trying to connect a DVD/USB through virtual media even though the virtual
media is currently not in use?
The error message is displayed if Remote File Share (RFS) feature is also in use. At a time, you can use RFS or Virtual Media and
not both.
vFlash SD Card
When is the vFlash SD card locked?
The vFlash SD card is locked when an operation is in-progress. For example, during an initialize operation.
SNMP Authentication
Why is the message 'Remote Access: SNMP Authentication Failure' displayed?
As part of discovery, IT Assistant attempts to verify the get and set community names of the device. In IT Assistant, you have
the get community name = public and the set community name = private. By default, the SNMP agent community name for
iDRAC agent is public. When IT Assistant sends out a set request, the iDRAC agent generates the SNMP authentication error
because it accepts requests only from community = public.
To prevent SNMP authentication errors from being generated, you must enter community names that are accepted by the
agent. Since the iDRAC only allows one community name, you must use the same get and set community name for IT Assistant
discovery setup.
Storage Devices
Information for all the storage devices connected to the system are not displayed and OpenManage Storage
Management displays more storage devices that iDRAC. Why?
iDRAC displays information for only the Comprehensive Embedded Management (CEM) supported devices.
iDRAC Service Module
Before installing or running the iDRAC Service Module, should the Open Manage Server Administrator be
uninstalled?
No you do not have to uninstall Server Administrator. Before you install or run the iDRAC Service Module, make sure that you
have stopped the features of Server Administrator that the iDRAC Service Module provides.
How to check whether iDRAC Service Module is installed in the system?
To know if the iDRAC Service Module is installed on the system,
On Windows:
282
Frequently Asked Questions