Release Notes
Issue 5:
Description
Cannot set VNC password with quotes.
Resolution
Do not use double quotes for the VNC password.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 6:
Description
When you run the following command, it does not display the list of controllers when the host system is
turned off.
racadm storage get controller command
Resolution
Use the following command to view the list of controllers available in the system:
racadm get storage.controller.<index>
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 7:
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the
sequence of events reported in the Lifecycle Log (or corresponding SNMP traps) for storage devices may
not exactly match the sequence in which they occurred.
Resolution
Check the current state or attribute of the storage device using any of the iDRAC8 interfaces (example,
iDRAC8 Web interface, RACADM, and so on).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 8:
Description
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a
non-redundant path, the reported connected port value of the enclosures may not be accurate.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 9:
Description
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its
components (that is, EMM, PSU, fan, and temperature sensors) is reported as critical.