Release Notes

Resolution
Retry the operation.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers.
Issue 3
Description
Some of the supported components are not displayed on the Firmware Update-> View Current
Versions page.
Resolution
Restart the server and open View Current Versions page.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers
Issue 4
Description
If a Mellanox card is present in the system, then under Network Settings, the port number must be
displayed as Port 1 and Port 2, because it is a dual port. But, the port number is displayed as Port 1 for
both the ports or the port numbers are not displayed.
Resolution
To distinguish between the port numbers, see the MAC address or the Device Settings.
You can access Device Settings in the following methods:
During POST, press <F2>, and then click System Setup.
On the Lifecycle Controller Home page, click System Setup, and then click Advanced Hardware
Configuration.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers
Issue 5
Description
After you successfully update the firmware of a CPLD on a modular server, and then perform a firmware
update operation of a component that requires a system restart (such as BIOS), the server is
automatically and repeatedly restarted.
Resolution
Perform a Power Cycle operation on the server.
Versions/Systems Affected
All LCsupported Dell PowerEdge servers.
Issue 6
Description
Lifecycle Controller may go into an infinite loop when a network operation is tried with an incorrect NFS
share name.
Resolution
Restart Lifecycle Controller and retry the operation with the correct NFS share name details.
Versions/Systems Affected