Release Notes

Physical Disks->Setup
Physical Disks->Identify
Controllers->Setup
Controllers->Troubleshooting
Virtual Disks->Create
Virtual Disks->Manage
Resolution
Use RACADM, WSMAN, or OpenManage Storage Management to perform storage configuration
operations.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 22:
Description
When an IO Identity Optimization Job for Network and Fibre Channel adapters is running, iDRAC does
not apply persistence policy for the host power events (cold or warm reset) that occur when the job is
running.
Resolution
You can apply persistence policy by manually performing the host power event (cold, warm, ac cycle
reset) after the job is performed completely.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and Network or Fibre Channel adapters.
Issue 23:
Description
Using IO Identity Optimization job, you cannot configure the value “0” for all SubnetPrefix attributes on
Broadcom 10G Network Adapters. Issue is observed only when Broadcom 10G adapters are in IPv6
mode. Also, you cannot clear the SubnetPrefix values using persistence policy.
Resolution
Disable IO Identity Optimization and run a configure job again to apply value “0” to SubnetPrefix
attributes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and Broadcom 10G adapters.
Issue 24:
Description
Using persistence policy feature, you cannot clear IscsiInitiatorGateway, IscsiInitiatorIpAddr,
IscsiInitiatorIpv4Addr on Emulex NDC adapter.
Resolution
Disable the IO Identity Optimization and run a configure job with 0.0.0.0 values to the listed values.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and Emulex NDC adapters.