Release Notes
Resolution
On system with the CIFS share:
1. Start the Registry Editor (regedt32.exe).
2. Locate the following key in the Windows registry:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\LanmanServer\Parameters
3. Add the following entries to the registry key
- DWORD key DisableStrictNameChecking
- Add with value 1 (decimal) to enable file sharing.
4. Reboot your computer for the changes to take effect.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 14:
Description
iDRAC8 user interfaces (example, iDRAC8 Web interface, RACADM and so on) does not display the newer
storage enclosure or backplane firmware version when its firmware is updated through the operating
system using DUP.
Resolution
To update the storage inventory, perform a server power cycle (cold boot) or reset the iDRAC.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8 and out-of-band enabled PERC storage controllers.
Issue 15:
Description
Power Cap (in Watts, BTU/hr %) is not accepting values preceding with zero (0).
Resolution
Do not precede a zero (0) while entering value for Power Cap in the Power Configuration page.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 16:
Description
In the Network Interfaces page > Host OS Network Interfaces section, the link to the Network Devices
page is not available for embedded LOM.
Resolution
In the Network Devices page, see the FQDD detail that does not have the link.
Version/Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 17:
Description
In iDRAC Web interface, few port number fields accept duplicate port numbers.
Resolution
Check for duplicate port numbers before entering the port number.