Dell OpenManage SNMP Reference Guide for iDRAC8
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction........................................................................................................... 5 What’s New in This Release...................................................................................................................5 Supported SNMP Versions.................................................................................................................... 5 Managed Object Used in This Document..........................................................
Configuration Trap Group............................................................................................................ 44 4 Standard Data Type Definitions.......................................................................45 Common Data Types..........................................................................................................................45 Variables with Data Types of State Capabilities and State Capabilities Unique................................
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC8. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
Managed Object Used in This Document The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose: MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.
Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1.
Type of Definition See Systems management terms, acronyms, and commonly managed components referred to in this reference guide. Glossary available on the Dell Support web site at dell.com/ support/manuals. Server Administrator-standard data types that specify variable values in this reference guide. Appendix A, Standard Data Type Definitions. Basic Terminology It is important to have a good understanding of the key technical terms used in this guide.
example is the section of this reference guide entitled Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID. The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value.
Access Read-only Table 8. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 9. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis.
SNMP Traps 2 SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 10. Trap Variables Variable Name alertSystem Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1 Description Identifies the system generating the alert. Syntax DisplayString Table 11. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert.
Syntax Octet String The following variables show the Enhanced varbinds: Table 16. Message ID Variable Name alertMsgID Object ID 1.3.6.1.4.1.674.10892.4.5000.10.7 Description Specifies the enhanced message ID for the object generating the alert. Syntax DisplayString Table 17. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 18.
Description Line Item Explanation Action requested was: Reboot, shutdown OS first Additional details: Specifies possible additional details about the specified device, for example: Additional details: Memory device: DIMM_1A Serial number: 11111111 Memory device: DIMM_1B Serial number: 22222222 Specifies any additional power supply information pertaining to the event, for example: Power supply input AC is off, Power supply
Description Line Item Explanation Discrete voltage state: Specifies the state of the voltage sensor, for example: Discrete voltage state: Good Fan sensor value: Specifies the fan speed in revolutions per minute (RPMs) or On/Off, for example: Fan sensor value (in RPM): 2600 Fan sensor value: Off Log type: Specifies the type of hardware log, for example: Log type: Embedded Server Management (ESM) Memory device bank location: Specifies the name of th
Description Line Item Explanation Processor sensor status: Configuration error Redundancy unit: Specifies the location of the redundant power supply or cooling unit in the chassis, for example: Redundancy unit: Fan Enclosure SD card device type: Specifies the type of SD card device, for example: SD card device type: Hypervisor SD card state: Specifies the state of the SD card, for example: SD card state: Present, Failed Sen
Table 21. RAC Traps TrapID Name Description Severity Category Cause Support ed by RAC Platfor m 0 CodeStart SNMP agent is Informatio initializing n itself Status RAC power on or reset. All 1 Authenticati Failure on Request received with an invalid community name Error SNMP request with an invalid community name. All 1001 alertDrscTe The RAC Informatio st TrapEvent generated a n test trap event in response to a user request Status A test SNMP trap generated by a RAC.
TrapID Name Description Severity Category Cause Support ed by RAC Platfor m 1018 alertDrscSE L 90 percentFull The RAC system event log is 90% full Major Status RAC detected system event log is 90% full. All 1018 alertDrscSE L 90 percentFull The RAC system event log is 90% full Major Status RAC detected system event log is 90% full.
TrapID Description Severity 65799 Over-Temperature warning (Upper non-critical, going high) Minor 65927 Over-Temperature warning Cleared Information 65801 Over-Temperature Problem (Upper Critical - going high) Critical 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cl
TrapID Description Severity 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low (Predictive Failure) Warning 2715520 Battery Low (Predictive Failure) Cleared Information 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Information 487169 CPU Thermal Trip (Over Temperature Shutdown) Critical 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information
TrapID Description Severity 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Information 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Information 789249 Memory Redundancy has been Lost Critical 789248 Memory redundancy has returned to Normal Information 1076994 System Event Log (SEL) Cleared Information 1076996 System Event Log (SEL) Full (Logging
3 iDRAC8 MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRACSMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 8 (iDRAC8). This MIB provides management data that allows you to monitor devices and software on a system via an out-ofband connection to the iDRAC8 of a system. NOTE: From iDRAC7 firmware release r1.30.
iDRAC8 SNMP Data Security Features iDRAC8 firmware supports the following data security features: • SNMP security lockout feature – iDRAC8 supports a simply, non-configurable SNMP security lockout feature. If more than six SNMPv3 USM authentication failures occur within a 2-minute window, then the iDRAC8 SNMP Agent blocks all subsequent SNMPv3 requests/queries for 10 minutes. • Restriction of access to sensitive data – Some of the MIB data that iDRAC8 supports can only be accessed via SNMPv3 queries.
Syntax StringType Access Read-only Table 24. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card. Syntax StringType Access Read-only Table 25. RAC Manufacturer Name racManufacturer Object ID 1.3.6.1.4.1.674.10892.5.1.1.4.0 Description This attribute defines the product manufacturer of a remote access card. Syntax StringType Access Read-only Table 26.
Table 29. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card. Syntax StringType Access Read-only Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty.
Table 33. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 34. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system. Syntax StringType Access Read-only Table 35. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.
Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 39. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 40. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.0 Description This attribute defines the Rack locator of the system.
Table 44. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 45. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 46.
Access Read-only Table 49. System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.0 Description This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included. Syntax ObjectStatusEnum Access Read-only Table 50. Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card.
The iDRAC8 generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console. Each event generates an identifier called the trap ID and a list of trap variables that provide additional details about the event. The trap variables are listed in the following on Trap Variables.
Table 54. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 55. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString Table 56. Alert System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.5.3.1.
Syntax StringType Table 60. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For blade systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). Syntax DisplayString System Trap Group The System Trap Group contains traps that fall under the System Health event category of the iDRAC8.
TrapID Description Category SubCategory Severity Battery has failed or battery is absent. System Health Battery Event Critical Category SubCategory Severity System Health Processor Information al System Health Processor Minor System Health Processor Critical Description Category SubCategory Severity Processor device is absent. System Health Proc Absent Critical Description Category SubCategory Severity Fan information. System Health Fan Event Information al Fan warning.
TrapID Description Category SubCategory Severity 2538 Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event. System Health Fiber Channel Critical Category SubCategory Severity System Health Hardware Config Information al System Health Hardware Config Minor System Health Hardware Config Critical Category SubCategory Severity Memory device informational event. System Health Memory Information al Memory device status is noncritical.
TrapID Description Category SubCategory Severity 2089 Network failure or critical event. System Health NIC Config Critical Description Category SubCategory Severity An OS graceful stop occurred; or an OS graceful shut-down occurred. System Health OS Event Information al A critical stop occurred System Health during OS load; or a runtime critical stop occurred. OS Event Critical Description Category SubCategory Severity An informational event was detected for a PCI device.
Table 74. BIOS POST Trap TrapID Description Category SubCategory Severity System BIOS detected a failure. System Health BIOS POST Critical Description Category SubCategory Severity Power supply has returned to normal. System Health Power Supply Information al Power supply has detected a System Health warning. Power Supply Minor Power supply has detected a System Health failure. Power Supply Critical Bios Post Failure 2425 Table 75.
Table 78. Redundancy Traps TrapID Description Category SubCategory Severity Redundancy information. System Health Redundancy Information al Redundancy is degraded. System Health Redundancy Minor Redundancy is lost.
TrapID Description Category SubCategory Severity 2489 Integrated Dual SD Module redundancy is lost. System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Information al Security failure or critical event. System Health Security Event Critical Category SubCategory Severity System Health Sys Event Log Information al System Event Log warning.
Table 85. Temperature Statistics Traps TrapID Description Category SubCategory Severity Temperature Statistics Minor Temperature Statistics Critical Category SubCategory Severity System Health vFlash Event Information al System Health vFlash Event Minor System Health vFlash Event Critical Category SubCategory Severity vFlash Media device is absent. System Health vFlash Absent Information al Description Category SubCategory Severity RAC information.
Table 89. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage sensor reading is within range. System Health Voltage Information al Voltage sensor has detected System Health a warning value. Voltage Minor Voltage sensor has detected System Health a failure value. Voltage Critical Category SubCategory Severity System Health Performance Minor Voltage Probe Normal 2171 Voltage Probe Warning 2170 Voltage Probe Failure 2169 Table 90.
TrapID Description Category SubCategory Severity 4330 Controller warning. Storage Storage Contr Minor Controller failure. Storage Storage Contr Critical Description Category SubCategory Severity Storage Storage Enclosr Information al Storage Storage Enclosr Minor Enclosure failure. Storage Storage Enclosr Critical Description Category SubCategory Severity Fan information. Storage Fan Event Information al Fan warning. Storage Fan Event Minor Fan failure.
Table 96. Power Supply Traps TrapID Description Category SubCategory Severity Storage Power Supply Information al Storage Power Supply Minor Storage Power Supply Critical Category SubCategory Severity Storage Information al Storage Minor Storage Critical Category SubCategory Severity Storage Temperature Information al Storage Temperature Minor Storage Temperature Critical Storage Power Supply Information 4235 Power supply information.
Table 99. Virtual Disk Trap TrapID Description Category SubCategory Severity Storage Virtual Disk Information al Storage Virtual Disk Minor Storage Virtual Disk Critical Storage VirtualDisk Information 4355 Virtual disk information. Storage Virtual Disk Warning 4354 Virtual disk warning. Storage Virtual Disk Failure 4353 Virtual disk failure. Updates Trap Group The Updates Trap Group contains traps that fall under the Updates event category of iDRAC8.
Table 103. iDRAC IP Address Change Trap TrapID Description Category SubCategory Severity iDRAC IP address has changed. Audit DRAC IP Address Informational Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure. Audit Licensing Critical Category SubCategory Severity Audit System Info Informational iDRAC IP Address Change 8499 Table 104.
Standard Data Type Definitions 4 This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 108. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled.
ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 111. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant.
the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4. Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuufff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds.