Release Notes
Scripting (all CLI related items)
Security
N/A
Storage and PERC
N/A
Support Assist and parts replacement
N/A
Updates
N/A
Important notes
Note 1:
Dell PowerEdge R230, R330, T130, and T330 systems are shipped with iDRAC 2.43.43.43. Downgrades of iDRAC firmware are
not allowed on these systems because older firmware versions do not support the new processors.
Known issues
• If you enumerate the enclosure view's WSMAN command on a system while one PSU-cable is removed, the primary
status of the enclosure view is reported as Healthy instead of Warning.
• After iDRAC reset or firmware update, the ServerPoweredOnTime (a property in RACADM and WS-MAN) may not be
populated until the host server is restarted.
• On performing warm boots, occasionally a message is displayed by BIOS indicating that there is a KCS failure (error
code UEFI0039). No action required for this error. The error is caused by the timing change in the response of the
daemons on the iDRAC. Rebooting the host restores normal boot behavior.
• Upon execution of racadm swinventory or racadm hwinventory command via a local RACADM interface, the inventory
details are not fetched if all the OS drives (A-Z) are mapped. Unmap an existing OS drive to resolve this issue.
• Using local RACADM proxy, if you configure a CMC user name that consists of a space, the command does not
successfully create the user name. Use CMC RACADM, Remote RACADM, or Remote RACADM proxy interface.
• Redfish response contains a HTTP header named Allow, when the HTTP response code is 405. The list may contain
PATCH, DELETE, POST, GET, HEAD values, but all of them may not be supported.
• If a requested resource is not present, HTTP response status code may not be always 404.
• Scrolling-down using the mouse does not work in VNC server.
• When a new PCIe SSD drive is hot plugged in an empty drive bay slot, PrepareToRemove or SecureErase features on
that drive fail unless the host is rebooted and it completes the CSIOR cycle.
• Sometimes, iDRAC logs the following message to the Lifecycle Controller log:
PWR2262: "The Intel Management Engine has reported an internal system error."
Also, it logs the following message within the next few minutes:
PWR2264: "The Intel Management Engine has reported normal system operation."
No action is required. All Dell PowerEdge systems with iDRAC7 and iDRAC8 are affected.
• Server Configuration Profile (SCP) Import and Preview configuration does not give details about the values that are
modified via SCP Redfish. These configuration details are not available via Redfish interface. For configuration details,
run the command - "racadm lclog viewconfigresult -j JID_xxxxxxxxxxxx".
• When you enumerate DCIM_NumericSensor using the WS-MAN interface, the SettableThreshold property displays 0,
which indicates that the LowerThresholdNonCritical field can be set. However, for performance-statistic sensors, this is
not a settable field. For these sensors, you can only set the UpperThresholdNonCritical field, indicated by the value of 1.
• Sometimes, when using WSMAN, an "Internal SSL Error" is reported and the WSMAN command fails. If this happens,
retry the command to resolve the issue.